Product Details:
| Brand | Bioxia |
| External Size | 1350 mm X 740 mm X 660 mm |
| Internal Size | 900 mm X 550 mm X 500 mm |
| Interlock Size | 330 mm X 330 mm X 280 mm |
| Weight | 150 kg |
| Oxygen Controlled with Display | 0.0 % to 25.00 % |
| Power Input | 220-240V AC, 50 HZ |
Product Details:
| Brand | Bioxia |
| External Size | 900 mm X 740 mm X 660 mm |
| Internal Size | 650 mm X 500 mm X 500 mm |
| Interlock Size | 250 mm X 300 mm X 300 mm |
| Weight | 120 Kg |
| Oxygen Controlled with Display | 0.0 % to 25.00 % |
| Safety Features | Excess pressure relief valve, Temperature overshoot controller |
| Power Input | 220-240V AC, 50 HZ fitted with plug and resettable Over current breaker fitted for protection |
Main Workstation Capacity:
Interlock Capacity:
Safety Features:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | yes |
| Material | yes |
| Finishing | yes |
| Power Source | yes |
| Sizes | yes |
| Structure | yes |
| Country of Origin | Made in India |
1. These workstations allow us to isolate cells in a chamber that accurately maintains and controls temperature, humidity, oxygen & Carbon dioxide. With this workstation we will studied the most complex cell interactions under perfect hypoxic conditions.
2. Main Workstation Capacity: Up to 550 of 90mm X 15mm plates capacity
Inoculation working space : Should be 40 % of Total volume in addition to above space
3. Dimensions : L X D X H (aprox.) in mm
External : 1400X 700 X 740
Main Chamber : 900 X 540 X 570
Inter lock : 220 X 250 X 290
4. Inter lock Capacity:
Up to 35 of 90mm X 15mm plates capacity
Auto Inter lock cycle.
Interlock Cycle Time : 20 S
4. Air Lock/ Isolated/Interlock chamber, for inserting at least 35 of 90mm X 15mm plates at a time, with Proper leakproof door and handle
5. Oxygen Controlled with Display 1.0 % to 25 %
6. Digital Display :
I ) Touch Screen LCD Display for Monitoring as well as control : of Chamber pressure,
Temperature, Humidity, Water Level Indicator , gas cylinder pressure , Light 1 &
Light 2 shall be provided
II ) Said Touch Screen display should continuously indicate & controls:
I) Controls O2 from 1.0 % to 25.0 % in 0.1% increments
II) Controls CO2 from 1.0 % to 30.0%in 0.1% increments
III) Controls Pressure from 0.15 to 0.30 KPA increments
IV) Control of Temperature from ambient to 50 ° C
V) Control of Humidity from ambient to 85 % Rh
III ) Said LCD display simplifies the calibration process:
I) automatically calibrates O2 sensor through one touch screen control.
II) Provides rapid equalization.
III) Facilitates the download of data.
IV ) Said Touch Screen display allows hypoxic cycling:
I) Facilitating up to 4 different O2 and Co2
II) Concentrations through a user-defined sequence of time
III) Oxygen sensor and Co2 sensor shall be present in the main working chamber
V ) Workstation shall be supplied with Gas Control Software for