Product Details:
External Size | 900 mm X 740 mm X 660 mm |
Internal Size | 650 mm X 500 mm X 500 mm |
Interlock Size | 250 mm X 300 mm X 300 mm |
Weight | 120 Kg |
Oxygen Controlled with Display | 0.0 % to 25.00 % |
Power Input | 220-240V AC, 50 HZ fitted with plug and resettable Over current breaker fitted for protection |
Construction: Durable, Non-Corrosive, Opaque sheet of Acrylic Resin of 8 mm thickness for the entire body, except front panel of 8 mm thick similar acrylic resin but a transparent sheet, for better visibility and insulation.
Features:- To make the chamber oxygen-free, automatic forced amplifying purging system for Main Chamber as well as Interlock chamber, with adjustable purging period is provided
- To make the chamber oxygen-free at faster rate, additional facility to condition the workstation atmosphere using Palladium Catalyst, provided
- Seamless stainless steel removable work surface.
- Heating element along with a controller to maintain inside chamber temperature with 25°C to 45°C, and temperature uniformity of ± 1.0 °C and relative humidity up to 90% Facility for temperature overshoot controller
- Vacuum pump along with connection pipe of 1mm thickness is provided to remove air from Interlock Chamber
- Leak-proof arrangement from front-transparent-penal, for access inside the chamber, for easy & comfortable handling/operation inside the chamber
- Inlet Option for Two Separate gases, one for premixed anaerobic gas & another for Nitrogen Gas
- Utility port with flexible hose for manual purging by Nitrogen, inside the chamber, operated by foot switch outside chamber Similar Foot Switch provided for operation for gas nozzle ports & spot lamp inside the chamber
- Two Electrical Sockets inside the chamber
- Automated Humidity controlled system: Humidity controlled with display
- Activated Detox ( Charcoal)to absorb the smell
- Heater for dehumidification
- Resettable Over current breaker fitted for protection
- Digital Display
Additional Features for Variable Atmospheric Workstation:- Provisions of using 4 gases separately ( Nitrogen, Carbon dioxide, Air & 10 % Hydrogen + 90 % Nitrogen Mix ) with built-in gas sensing technology to maintain the precise concentration of different gases within the workstation
LCD full touch screen display Controlled for Control and monitoring of all parameters with password protection- Inbuilt Digital Oxygen Display
- Oxygen Controlled with Display 0.0 % to 23.0 % with 0.1 Increments
- Auto H2O level display
- Data Logging Facility with an accuracy of 1 minute
- Display status of single plate entry system
- More accurate Technology; indicator system with O2 sensor for display of real-time oxygen in a decimal percentage (% ) form, it helped to maintain accurate % of Oxygen in the chamber
- Auto Oxygen programming up to 5 cycles ( Hypoxic Cycle )
- System has inbuilt calibration facility of Temperature, Humidity, Chamber Pressure
- N2 Line Pressure
- Have automatic calibration of O2 Cell
Main Workstation Capacity:- Up to 350 of 96 well additional inoculation space for regular working
- Four supply ports inside the chamber
- Interlock Capacity:
- Interlock transfer Up to 25 plates of 90mm X 15mm
- Auto Interlock cycle
Safety Features:- Excess pressure relief valve